Next assembly:196805-01; drawing number:196763; this procurement control drawing describes the requirements for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment; the cable length shall be 97.83 to 98.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; the insertion shall be less than 8.5 db, maximum at 2.0 ghz; required connector per mil-prf 39012, p1:ptnc male, straight, passivated stainless steel, p2:ptnc male, straight, pasivated stainless steel; the cable shall with stand a pull test of 80 lbs. Minimum per mil-prf-39012
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w2; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w9; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w8; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w6; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w7; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w5; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w4; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w3; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w1; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
Mil-prf-39012/26 2nd end single conductor
Bcable assembly consists of wire, rg-58, cage code 16428, part number 8259; connector, cage code 81349, mil-prf-39012/16-0014; tubing, heat shrink marker, cage code 08fe7, part number 4406250001.
Mil-prf-39012/16-0014 both ends single conductor