Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
01a228414-02
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
21 single component single primary output
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
30 single component single primary input
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
4.90 microhenries single component single primary output
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
7.65 microhenries single component single primary input and 7.75 microhenries single component single primary input
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
2.5 megahertz single component
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Solid single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
5.560 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component single primary input and electrical single component single primary input
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component single primary output and electrical single component single primary output
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, fixed autotransformer type single component
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.08081 inches american wire gage single component single primary input
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.08081 inches american wire gage single component single primary output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 threaded stud and 2 wire lead