Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Regenerative blower
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Centrifugal Fan Assembly
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
12.520 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
12.550 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Countermeasures test set 4920015464181
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Terminal box
MRC:
The length of a straight line which passes through the center of the outlet,and terminates at the inside circumference.AJLW
Outlet Inside Diameter:
1.500 inches
MRC:
The static pressure measured at the air flow rate specified.AJLY
Static Pressure At Specificationified Air Flow Rate:
65.0 inches of water
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Guarded
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole and 2 flange
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Clockwise
MRC:
The rated capacity of air flow moved through the item.CQKX
Air Flow Rate:
127.0 cubic feet per minute
MRC:
Indicates the location of the outlet on the item.CRWJ
Outlet Location:
Bottom
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
230.0 ac or 460.0 ac
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
1.500 horsepower
MRC:
The direction in which the item discharges during operation.CXCB
Discharge Direction:
Horizontal
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
1-1/2in npt threaded inlet and outlet mounted opposite end of motor from the impeller housing; 71lbs shipping weight
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 and 50.0
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
13.570 inches
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum blade
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum housing
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum housing outside
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Fixed