Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Audio Frequency Transformer
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.187 inches single group
MRC:
The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
Impedance Rating In Ohms:
4000.0 single component single secondary
MRC:
The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
Impedance Rating In Ohms:
10000.0 single component single primary
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.875 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.938 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.688 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
2.370 inches single mounting facility single center group
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
32.0 milliamperes dc single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 wire lead