Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radio Frequency Amplifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
24.100 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.200 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.800 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
General purpose
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-0.0/+55.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Top of cabinet/counter
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
0.1
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
48.0 single voltage and 66.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
100.0 single voltage and 240.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The military service that initially procured the item from the contractor.KZTS
Cognizant Service:
Usaf