Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						1-2f1g41-150					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						The end identified above as the second end is the valve inlet
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Safety Relief Valve				
			 
			
										
					
						MRC:
						A measurement of the pipe size the item will accommodate.AAAR
					 
					
						Pipe Size Accommodated:
					
					
						0.500 inches 1st end					
				 
							
					
						MRC:
						A measurement of the pipe size the item will accommodate.AAAR
					 
					
						Pipe Size Accommodated:
					
					
						0.500 inches 2nd end					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
					 
					
						Thread Direction:
					
					
						Right-hand 2nd end					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
					 
					
						Thread Direction:
					
					
						Right-hand 1st end					
				 
							
					
						MRC:
						The part that controls the flow through the item.ADQU
					 
					
						Flow Control Device:
					
					
						Disk					
				 
							
					
						MRC:
						Indicates the type of housing on the item that accommodates the stem packing or spring.ADSR
					 
					
						Bonnet Type:
					
					
						Inside spring					
				 
							
					
						MRC:
						The means by which the bonnet is attached to the item.ADST
					 
					
						Bonnet Attachment Method:
					
					
						Integral					
				 
							
					
						MRC:
						The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
					 
					
						Maximum Operating Temp:
					
					
						1750.0 degrees fahrenheit single response					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
					 
					
						Connection Style:
					
					
						G46b plain (pipe) 2nd end					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
					 
					
						Connection Style:
					
					
						G9 plain, optional en (pipe)  1st end					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
					 
					
						Connection Style:
					
					
						Plain (pipe) 2nd end					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
					 
					
						Connection Style:
					
					
						Plain, optional en (pipe)  1st end					
				 
							
					
						MRC:
						The means used to control the operation of the valve.AQLR
					 
					
						Valve Operation Method:
					
					
						Automatic					
				 
							
					
						MRC:
						Indicates the type of connection/s/.AWLS
					 
					
						Connection Type:
					
					
						Threaded external pipe 2nd end					
				 
							
					
						MRC:
						Indicates the type of connection/s/.AWLS
					 
					
						Connection Type:
					
					
						Threaded internal pipe 1st end					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Pressure tight outlet side					
				 
							
					
						MRC:
						The maximum pressure at which the item is rated for operation.CQGM
					 
					
						Maximum Operating Pressure:
					
					
						300.0 pounds per square inch single response					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.500 inches 1st end					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.500 inches 2nd end					
				 
							
					
						MRC:
						The predetermined pressure at which the item is calibrated to open.CSDC
					 
					
						Opening Pressure Setting:
					
					
						150.0 pounds per square inch					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper alloy body					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Stainless steel flow control device					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Stainless steel seat					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Water-oil-gas single response					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Err-090					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Angle					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Npt 2nd end					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Npt 1st end