Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Foot Valve				
			 
			
										
					
						MRC:
						The basic material of which the body is fabricated.AAFZ
					 
					
						Body Material:
					
					
						Bronze					
				 
							
					
						MRC:
						The maximum pressure at which an item is designed to operate.AAJJ
					 
					
						Maximum Operating Pressure:
					
					
						250.0 pounds per square inch					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical (screwed)					
				 
							
					
						MRC:
						Items furnished as accessories which are not specified elsewhere.ABFF
					 
					
						Furnished Items:
					
					
						Filter screen					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Water,  oil or gas					
				 
							
					
						MRC:
						A narrative description of the type of end connection.ACKM
					 
					
						First End Connection Type:
					
					
						Threaded internal pipe					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
					 
					
						First End Style Designator:
					
					
						Plain					
				 
							
					
						MRC:
						The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACLG
					 
					
						First End Pipe Size Accommodated:
					
					
						1.000 inches					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
					 
					
						First End Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
					 
					
						Body Outside Diameter:
					
					
						1.750 inches 					
				 
							
					
						MRC:
						The part that controls the flow through the item.ADQU
					 
					
						Flow Control Device:
					
					
						Poppet					
				 
							
					
						MRC:
						The number of end connections included in the item.ADQZ
					 
					
						End Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the location of the valve loading spring as related to the valve body.AFLK
					 
					
						Valve Loading Spring Location:
					
					
						Internal