Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Engine Air Duct Heater
MRC:
The maximum output of the unit,expressed in british thermal units per hour.ABAK
Heat Delivery Rate In Btu Per Hour:
85000.000
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
2.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
1 electric motor w/blower
MRC:
An indication of whether or not a pump is included.ALTE
Pump:
Not included
MRC:
The means used to feed fuel to the burner.ARHM
Burner Fuel Feed Method:
Pressure
MRC:
An indication of whether or not an integral fuel tank is included.ARHN
Err Default:
Err default
MRC:
An indication of whether or not an integral fuel tank is included.ARHN
Integral Fuel Tank:
Not included
MRC:
An indication of whether or not a mounted heater switch is included.ARHR
Mounted Heater Switch:
Not included
MRC:
Indicates whether or not an automatic temperature control is included.ARHS
Automatic Tempurature Control:
Included
MRC:
The number of connections provided on the air duct.ARHT
Err Default:
Err default
MRC:
The number of connections provided on the air duct.ARHT
Air Duct Connection Quantity:
3
MRC:
The design of the air duct connection.ARHW
Err Default:
Err default
MRC:
The design of the air duct connection.ARHW
Air Duct Connection Design:
Angled
MRC:
The design of the air duct connection.ARHW
Air Duct Connection Design:
Straight
MRC:
Indicates the type of angle connection(s) included on the item.ARHX
Err Default:
Err default
MRC:
Indicates the type of angle connection(s) included on the item.ARHX
Angle Connection Type:
Stationary
MRC:
An indication of whether or not a connection thread provision for the air duct is included.ARHY
Err Default:
Err default
MRC:
An indication of whether or not a connection thread provision for the air duct is included.ARHY
Air Duct Connection Thread Provision:
Not included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
24.000
MRC:
Indicates the type of fuel(s) for which the item is designed.FUEL
Fuel Type:
Gasoline
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Heater, engine accessory nonaircraft