Control lines are used to test and verify the monitors operation; indicates multiple out of tolerance conditions simultaneously; vibration, 1.5 g at 5hz, 6.0 g at 14hz, 1.5 g at 30hz
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Voltage Deviation Monitor
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.250 inches
MRC:
The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
Vibration Resistance Amplitude:
1.5 gravitational units and 6.0 gravitational units and 1.5 gravitational units
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
30.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+10.0/+50.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-40.0/+75.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
380.5 single voltage and 419.5 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
108.0 single voltage and 118.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Three phase power monitor module for the detection of abnormal input power conditions of frequency, voltage, and phase sequence for lantirn se