Provides ppi sweep ranges of 5, 10, 20, 40, 60, and 200 miles; provides adjustable electronic cursors on search indicators
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Pulse-sweep Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.312 inches
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/mpn-14, an/mpa-9, an/mpa-13
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
15000.000 ohms 2nd output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
200000.000 ohms 1st output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms 3rd output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms 4th output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
0.500 microseconds 3rd output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
0.500 microseconds 4th output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
125.000 microseconds 2nd output channel err-100 and 2500.000 microseconds 2nd output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
125.000 microseconds 1st output channel err-100 and 2500.000 microseconds 1st output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Negative 2nd output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive 1st output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive 3rd output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive 4th output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
1100.000 pulses per second 2nd output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
275.000 pulses per second 1st output channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
20.000 volts 2nd output channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
20.000 volts 3rd output channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
25.000 volts 1st output channel err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st output channel sweep err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd output channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
3rd output channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
4th output channel range err-100
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Sawtooth and pulse, gate and pulse, variable width and pulse, sweep
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
60.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
28.0 3rd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
300.0 2nd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
425.0 1st voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-210.0 12th voltage err-100
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
117.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description: