Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Globe Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
Indicates the type of housing on the item that accommodates the stem packing or spring.ADSR
Bonnet Type:
Inside screw
MRC:
The means by which the bonnet is attached to the item.ADST
Bonnet Attachment Method:
Threaded
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Manual
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded external boss 1st end
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
6000.0 pounds per square inch single response
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Quality control iaw navships 0948-045-7010 material identification and control instruction for level 1 items