Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.438 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
20 single component single primary
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Hollow single component
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.594 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Cdwq-nx4000tub
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component single primary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Special marking
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.02010 inches american wire gage single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead