Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Inner conveying tube material-rubber,  buna-n
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Nonmetallic Hose Assembly				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
					 
					
						Cross Sectional Shape:
					
					
						Round					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						2b 1st end					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
					 
					
						Thread Direction:
					
					
						Right-hand 2nd end					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
					 
					
						Thread Direction:
					
					
						Right-hand 1st end					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
					 
					
						Inside Diameter:
					
					
						0.406 inches 					
				 
							
					
						MRC:
						A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
					 
					
						Tempurature Rating:
					
					
						-40.0 degrees fahrenheit single response and 250.0 degrees fahrenheit single response					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
					 
					
						Outside Diameter:
					
					
						0.766 inches 					
				 
							
					
						MRC:
						The minimum inside bending radius formed without stressing or deformation of a flexible item.ACKH
					 
					
						Minimum Inside Bending Radius:
					
					
						4.625 inches					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
					 
					
						Connection Style:
					
					
						Inverted flare 2nd end					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
					 
					
						Connection Style:
					
					
						Swivel nut flare 1st end					
				 
							
					
						MRC:
						The physical configuration of the outside of the end connection.AKUU
					 
					
						End Connection Design:
					
					
						Straight 1st end					
				 
							
					
						MRC:
						The physical configuration of the outside of the end connection.AKUU
					 
					
						End Connection Design:
					
					
						Straight 2nd end					
				 
							
					
						MRC:
						The name of the fitting and/or component and the element, compound, or mixture of which it is fabricated.AKXL
					 
					
						End Fitting Component And Material:
					
					
						Complete fitting copper alloy all ends					
				 
							
					
						MRC:
						The name of the fitting and/or component and the plating, dip and/or coatingthat cannot be wiped off. plating and/or coating is any chemical and/or metallic additive, electrochemical or mild mechanical process which protects the surface.AKXM
					 
					
						Fitting Component And Surface Treatment:
					
					
						Complete fitting cadmium 1st end					
				 
							
					
						MRC:
						Indicates the type of connection/s/.AWLS
					 
					
						Connection Type:
					
					
						Threaded external pipe 2nd end					
				 
							
					
						MRC:
						Indicates the type of connection/s/.AWLS
					 
					
						Connection Type:
					
					
						Threaded internal tube 1st end					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Perforated outer cover					
				 
							
					
						MRC:
						Indicates whether or not the second end is identical to the first end.CQBB
					 
					
						Second End Relationship With First End:
					
					
						Not identical					
				 
							
					
						MRC:
						The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
					 
					
						Burst Test Pressure:
					
					
						8000.0 pounds per square inch					
				 
							
					
						MRC:
						The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
					 
					
						Layer Composition And Location:
					
					
						1st layer braided cotton cord err-100					
				 
							
					
						MRC:
						The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
					 
					
						Layer Composition And Location:
					
					
						2nd layer braided steel wire err-100					
				 
							
					
						MRC:
						The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
					 
					
						Layer Composition And Location:
					
					
						3rd layer braided cotton cord err-100					
				 
							
					
						MRC:
						The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
					 
					
						Layer Composition And Location:
					
					
						Outer layer molded rubber,  chloroprene err-100					
				 
							
					
						MRC:
						The maximum pressure at which the item is rated for operation.CQGM
					 
					
						Maximum Operating Pressure:
					
					
						2000.0 pounds per square inch					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.375 inches 2nd end					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.750 inches 1st end					
				 
							
					
						MRC:
						The angle of the end surface upon which the mated surface seats.CQRB
					 
					
						Seat Angle:
					
					
						37.0 degrees 1st end					
				 
							
					
						MRC:
						The ultimate maximum vacuum,expressed in terms of absolute pressure,that may be produced by or applied to an item.CRSM
					 
					
						Vacuum In Torr:
					
					
						30.0					
				 
							
					
						MRC:
						The condition of the item with respect to the texture of the inner surface.CRWL
					 
					
						Inside Surface Condition:
					
					
						Smooth					
				 
							
					
						MRC:
						The means used and the measurement of the longest dimension of an item.CRXX
					 
					
						Measuring Method And Length:
					
					
						55.000 inches  working					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Nptf 2nd end					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Unf 1st end