Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Positive terminal common to coils
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electrical Solenoid				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical frame					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						1.281 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						0.950 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.750 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Metal					
				 
							
					
						MRC:
						Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
					 
					
						Case Surface Treatment:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.125 inches 					
				 
							
					
						MRC:
						The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
					 
					
						Maximum Operating Temp:
					
					
						125.0 degrees celsius					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Hermetically sealed					
				 
							
					
						MRC:
						The number of magnetic coils provided.APAF
					 
					
						Magnetic Coil Quantity:
					
					
						2					
				 
							
					
						MRC:
						A measurement of the opposition to the flow of direct or alternating current.APCC
					 
					
						Electrical Resistance:
					
					
						8.00 ohms 					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Intermittent					
				 
							
					
						MRC:
						The position of the terminal/s/ for making connection to an item.APXH
					 
					
						Terminal Location:
					
					
						End opposite actuator					
				 
							
					
						MRC:
						The voltage rating at which the item is designed to operate,expressed in volts.ASXH
					 
					
						Voltage Rating In Volts:
					
					
						30.0 dc 					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 unthreaded hole					
				 
							
					
						MRC:
						The amount of current for which the item is designed.AXNP
					 
					
						Current Rating:
					
					
						3.000 amperes 					
				 
							
					
						MRC:
						The movement of the actuator when force is applied.CNXT
					 
					
						Actuator Stroke Type:
					
					
						Pull					
				 
							
					
						MRC:
						The amount of linear force delivered.CNXW
					 
					
						Linear Force Delivered:
					
					
						2.50 pounds					
				 
							
					
						MRC:
						Indicates the type of means provided for connection of the power takeoff.CNXX
					 
					
						Power Takeoff Connection Type:
					
					
						Tee shape					
				 
							
					
						MRC:
						The maximum linear travel from the de-energized to the energized position.CNYD
					 
					
						Energizing Stroke Maximum Length:
					
					
						0.325 inches					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Four position rectangular					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						3 solder stud