Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Temperature Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum alloy
MRC:
The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
Stem Material:
Aluminum alloy
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
0.500-14 npt
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Aluminum alloy
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Diaphragm
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Rubber, synthetic
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
An indication of the action of a two-way valve.AEVM
Two-way Valve Action:
Direct acting
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
25.000 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
0.850 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.188 inches
MRC:
The element,compound,or mixture of which the bulb is fabricated.AEVW
Bulb Material:
Copper alloy
MRC:
An indication of whether or not the temperature is adjustable.AEVX
Tempurature Adjustability:
Not adjustable
MRC:
The basic design type of the thermostatic element used in transmitting the temperature of a liquid or gas.AEWJ
Thermostatic Element:
Integral w/valve