Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					El Engine Starter Relay-solenoid				
			 
			
										
					
						MRC:
						A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
					 
					
						Mounting Slot Width:
					
					
						0.281 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
					 
					
						Mounting Slot Length:
					
					
						0.343 inches 					
				 
							
					
						MRC:
						An indication of whether or not an item is capable of operation while submerged.AHZV
					 
					
						Submersibility:
					
					
						Nonsubmersible					
				 
							
					
						MRC:
						The distance between the mounting facilities.ARKQ
					 
					
						Mounting Facility Spacing:
					
					
						1.750 in. C to c 66 degrees apart on 2.562 in. Radius					
				 
							
					
						MRC:
						The nominal value(s) of potential for which the item is rated.AWYG
					 
					
						Voltage Rating:
					
					
						24.0 volts					
				 
							
					
						MRC:
						The amount of current required to activate the item.AXAZ
					 
					
						Pull-in Current:
					
					
						Between 41.6 amperes and 45.8 amperes 					
				 
							
					
						MRC:
						The amount of current required to maintain operation of the item.AXBA
					 
					
						Hold-in Current:
					
					
						7.3  volt-ampere and 8.3  microwatts					
				 
							
					
						MRC:
						The measured distance of the plunger stroke.AXBD
					 
					
						Plunger Stroke Length:
					
					
						0.750 inches 					
				 
							
					
						MRC:
						An indication of whether or not engaging linkage is included.AXBE
					 
					
						Engaging Linkage:
					
					
						Not included					
				 
							
					
						MRC:
						Designates the thread diameter and number of threads per measurement scale of the accommodated linkage threaded hole.AXBY
					 
					
						Accommodated Linkage Threaded Hole Thread Size:
					
					
						1/2-20					
				 
							
					
						MRC:
						An indication of whether or not the item includes provisions for manually closing the contacts.AXCC
					 
					
						Contact Manual Closing Provision:
					
					
						Not included					
				 
							
					
						MRC:
						The number of control terminals provided.AXCD
					 
					
						Control Terminal Quantity:
					
					
						2					
				 
							
					
						MRC:
						Indicates the type of control terminal/s/ provided.AXCE
					 
					
						Control Terminal Type:
					
					
						Stud					
				 
							
					
						MRC:
						An indication of whether or not a grounded control terminal is included.AXCF
					 
					
						Grounded Control Terminal:
					
					
						Included					
				 
							
					
						MRC:
						The number of main terminals provided.AXHJ
					 
					
						Main Terminal Quantity:
					
					
						2					
				 
							
					
						MRC:
						Indicates the type of main terminal/s/ provided.AXHK
					 
					
						Main Terminal Type:
					
					
						Stud					
				 
							
					
						MRC:
						The number of control terminals that are internally connected to the main terminals.AXHM
					 
					
						Control Terminal Quantity Internally Connected To Main Terminal:
					
					
						1					
				 
							
					
						MRC:
						The diameter of the motor for which the rigid mount is designed.AXHN
					 
					
						Motor Diameter For Which Rigid Mount Is Designed:
					
					
						5.120 inches 					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 slot