Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						1128scsea811-1					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Amplifier				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						7.500 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						2.723 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						3.125 inches 					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						+5.0/+33.0					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						+5.0 to 33.0					
				 
							
					
						MRC:
						The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
					 
					
						Vibration Resistance Amplitude:
					
					
						1.0 gravitational units					
				 
							
					
						MRC:
						The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
					 
					
						Shock Resistance Rating In Gravitational Units:
					
					
						20.0					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0 to 55.0 degrees celsius					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Hours					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Rectangular or square					
				 
							
					
						MRC:
						The maximum altitude at which the item is rated to function.AKAE
					 
					
						Maximum Operating Altitude Rating:
					
					
						10000.0 feet					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Mechanical					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						45.0 megahertz  operating channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						280.0 megahertz  operating channel					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						45.0 megahertz  operating channel					
				 
							
					
						MRC:
						The increase in energy from the input to the output.BHTL
					 
					
						Overall Gain:
					
					
						10.0 decibels					
				 
							
					
						MRC:
						The increase in energy from the input to the output.BHTL
					 
					
						Overall Gain:
					
					
						30.0 decibels					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						50.000 ohms operating channel					
				 
							
					
						MRC:
						The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
					 
					
						Shock Pulse Duration Time:
					
					
						11.0 milliseconds					
				 
							
					
						MRC:
						The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
					 
					
						Shock Pulse Duration Time:
					
					
						9.0 milliseconds					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						28.5  2nd voltage					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						33.0  2nd voltage err-100					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						5.7  1st voltage err-100					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						6.6  1st voltage err-100					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						33.0  2nd voltage					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						5.7  1st voltage					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						6.6  1st voltage					
				 
							
					
						MRC:
						The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
					 
					
						Fsc Application Data:
					
					
						Test console test set, countermeasures					
				 
							
					
						MRC:
						A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
					 
					
						Reference Number Differentiating Characteristics:
					
					
						As modified by mfg source control fscm 26512 part no. 1128scsea811-1