Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Fluid Filter				
			 
			
							
										
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						4.680 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						2.310 inches 					
				 
							
					
						MRC:
						The size of the smallest particle which the element is capable of removing from the fluid which passes through the filtering material.ADNH
					 
					
						Filtration Rating In Microns:
					
					
						25.0 absolute and 10.0 					
				 
							
					
						MRC:
						Indicates the design type of the item.APGF
					 
					
						Design Type:
					
					
						Reusable					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Air bleed valve					
				 
							
					
						MRC:
						The number of filtering elements provided.CCZM
					 
					
						Filtering Element Quantity:
					
					
						1					
				 
							
					
						MRC:
						The maximum pressure at which the item is rated for operation.CQGM
					 
					
						Maximum Operating Pressure:
					
					
						4500.0 pounds per square inch					
				 
							
					
						MRC:
						An indication of the structure or characteristic of the filtering media.CRXW
					 
					
						Filtering Media Design:
					
					
						Encased single filtering media response					
				 
							
					
						MRC:
						Indicates the type of connection on the first intake.CRXZ
					 
					
						First Intake Connection Type:
					
					
						Threaded internal tube side					
				 
							
					
						MRC:
						Indicates the type of connection on the first discharge.CSKS
					 
					
						First Discharge Connection Type:
					
					
						Threaded internal tube side					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combination from another by the number of threads per measurement scale for a specific diameter.CTDY
					 
					
						First Intake Thread Series Designator:
					
					
						Unf					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CTFF
					 
					
						First Discharge Thread Series Designator:
					
					
						Unf					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CTLG
					 
					
						First Discharge Thread Size:
					
					
						0.5625 inches					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CWAR
					 
					
						First Intake Thready Qty Per Inch (tpi):
					
					
						18					
				 
							
					
						MRC:
						The number of threads of the item,per linear inch,measured on a line parallel to the thread axis.CWBB
					 
					
						First Discharge Thready Qty Per Inch (tpi):
					
					
						18					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.CWNZ
					 
					
						First Intake Thread Class:
					
					
						3b					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.CWRH
					 
					
						First Discharge Thread Class:
					
					
						3b					
				 
							
					
						MRC:
						The direction of the thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.CXPF
					 
					
						First Intake Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						The direction of the thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.CXYG
					 
					
						First Discharge Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Aluminum alloy sediment bowl					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Stainless steel filtering medium					
				 
							
					
						MRC:
						The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
					 
					
						Fsc Application Data:
					
					
						Hydraulic instl, acft					
				 
							
					
						MRC:
						A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
					 
					
						Reference Number Differentiating Characteristics:
					
					
						As differentiated by source control dwg 114hs120