Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Compartment Vehicular Heater
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Wall suspended, room interior
MRC:
Indicates the heat medium type for which the unit is designed.ABAM
Heat Medium Type:
Air
MRC:
The number of heat outlets included on the item.ABAW
Heat Outlet Quantity:
1
MRC:
The direction in which the heat is discharged from the item.ABAX
Heat Delivery Direction:
Vertical
MRC:
Indicates the type of outlet(s) provided for the discharge of heat.ABAY
Heat Discharge Outlet Type:
Stationary
MRC:
Indicates the device/s/ provided for the purpose of directing the flow of heat.ABAZ
Heat Directing Device:
Jet nozzle
MRC:
Indicates the type of device(s) installed on or around the equipment which eliminates undesirable radio interference waves.ABFG
Radio Interference Suppression Type:
Army, mil-e-53301, radio suppression
MRC:
Indicates the location of the flue connection.ABFH
Flue Connection Location:
End connection
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
7.906 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
24.125 inches
MRC:
Indicates the type of device which controls the operation of the item.ALYC
Operating Control Type:
Hand switch
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
16.0
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Combustion chamber
MRC:
The means used for purposes of igniting.BLJC
Ignition Method:
Glow plug
MRC:
The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
Inclosure Material:
Stainless steel
MRC:
The amount of fuel the item is rated to consume per hour.CQTY
Fuel Consumption Rate Per Hour:
2.2 pounds
MRC:
The rate of heat delivery of the item.CQXD
Heat Delivery Rate:
60000.0 british thermal unit
MRC:
The means by which the fuel is fed to the item.CSGC
Fuel Feed Method:
Gravity
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
24.0
MRC:
Indicates the type of fuel(s) for which the item is designed.FUEL
Fuel Type:
80/87 octane gasoline and df-a arctic diesel fuel oil
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
12.750 inches
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Cadmium and paint
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Qq-p-416, type 1, class 2 federal specification 1st treatment response