Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Rotometer flowmeter
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Flow Rate Indicating Meter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.0 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Hose nipple
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
An indication of the type of meter.ANTH
Meter Type:
Float
MRC:
Indicates the design type of the item.APGF
Design Type:
Case
MRC:
The number of scales on the item.APSJ
Scale Quantity:
4
MRC:
The structural characteristic of the item.ARQS
Construction:
Inclosed w/sight window
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Hose nipple
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
An indication of whether or not a carrying handle is included.AXQG
Carrying Handle:
Not included
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
-0.1 to 30.0
MRC:
An indication of whether or not a base(s) is included.BHJT
Base:
Included
MRC:
Indicates the type of float used.BHSQ
Float Type:
Free
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Plastic
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Included
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Vertical
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Flow range: 0.2 through 30 lpm, acrylic body, accuracy is +/- 3 percent, includes: hose barb, tygon tubing and luer adapter.Measure airflow in air sampling application.