Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Features two alternate output voltages, 120/208vac; drawing name converter, frequency, electronic, 60hz to 400hz
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
20.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-16 trainer
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three 1st alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
187.2 ac pounds per hour dry 2nd alternate operating power rqmt and 228.8 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
108.0 ac pounds per hour dry 1st alternate operating power rqmt and 132.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
197.6 ac volts 1st power output and 218.4 ac volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
114.0 ac volts 2nd power output and 126.0 ac volts 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st alternate operating power rqmt and 65.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd alternate operating power rqmt and 65.0 hertz 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
380.0 hertz 1st power output and 420.0 hertz 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
380.0 hertz 2nd power output and 420.0 hertz 2nd power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Circuit breaker
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Three 1st power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Three 2nd power output