Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Two filtered functions
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Interfere Filter				
			 
			
										
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						+10.0/+500.0					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-55.0/+85.0 degrees celsius					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 1st radio interference50.0 ohms 2nd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 1st radio interference50.0 ohms 2nd radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						60.0 1st radio interference60.0 2nd radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						10.0 1st radio interference10.0 2nd radio interference					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						1.15 volts ac 1st radio interference1.15 volts ac 2nd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 1st radio interference inductance-capacitance 2nd radio interference					
				 
							
					
						MRC:
						The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
					 
					
						Maximum Tempurature Rise:
					
					
						25.0 degrees celsius					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 1st radio interference 1st function115.0 volts ac 2nd radio interference 2nd function					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
					 
					
						Body Material:
					
					
						Metal