Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Output disconnect relay
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
22.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Rf test set
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
208.0 ac pounds per hour wet single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
0.0 ac volts 1st power output and 260.0 ac volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
0.0 ac volts 2nd power output and 130.0 ac volts 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 63.0 hertz single operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
45.0 hertz single power output and 5.0 kilohertz single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-0.1/+55.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Ac voltmeter and circuit breaker and circuit overload protection device and on-off switch-indicator and over voltage protector and programmable and remote control and remote error sensing capability and voltage adjustment and over temperature protection
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
40.0 ac amperes single power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Single single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip single power output
MRC:
The program(s) for which the power supply is design compatible.CWWJ
Program Compatibility:
Ieee-488 gpib
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
55.0