Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radio Frequency Coil
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 2.370 inches and 2.430 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.155 inches single group and 0.161 inches single group
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
200.00 microhenries single component single winding
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Solid single component
MRC:
The designation describing the method used in forming the core.ACZR
Core Construction:
S0lid single component
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.330 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.950 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
130.0 degrees celsius
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.690 inches single mounting facility single center group and 1.710 inches single mounting facility single center group
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
5.5 amperes dc single component single winding
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
82577-h940031 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead