Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Autotransforme Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield brought out to terminal single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.594 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.750 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.875 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.250 inches single mounting facility single center group
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange single group and unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, fixed autotransformer type single component
MRC:
The points between the end terminals of a winding that provide electrical connection to intermediate values of the total winding.CQLC
Winding Tap Location (non-core):
Multiple taps w/o center tap single component single primary output
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
850.0 milliamperes ac single component single primary output and 120.0 milliamperes ac single component single primary output and 400.0 milliamperes ac single component single primary output and 220.0 milliamperes ac single component single primary output and 300.0 milliamperes ac single component single primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
115.00 ac pounds per hour wet single component single primary input
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
18.00 ac pounds per hour wet single component single primary output and 21.00 ac pounds per hour wet single component single primary output and 26.00 ac pounds per hour wet single component single primary output and 34.00 ac pounds per hour wet single component single primary output and 60.00 ac pounds per hour wet single component single primary output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 wire lead