Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
50kilohm load resistor on second section wiper
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Nonwire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical servo mounted
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
1.3120 inches
MRC:
The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
Pilot Length:
0.1320 inches
Undercut Diameter:
1.315 inches
Undercut Width:
0.0730 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.453 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.125 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.672 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.800 inches
Mounting Lip Diameter:
1.4370 inches
Mounting Lip Depth:
0.0930 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round
MRC:
Indicates the type of shaft bearing/s/ furnished.AEDZ
Shaft Bearing Type:
Ball
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
Effective Electrical Rotation In Deg Angular Rotation:
350.0
MRC:
The maximum amount of turning force required to initiate the actuator movement.AEFK
Maximum Starting Torque:
0.70 inch-ounces
MRC:
The maximum amount of force requred to maintain actuator movement.AEFL
Maximum Running Torque:
0.70 inch-ounces
MRC:
The total axial excursion of the shaft measured at the end of the shaft with a specified axial load applied alternately in the opposite directions.AEFY
Shaft End Play:
0.00500 inches
MRC:
The eccentricity of the shaft diameter with respect to the rotational axis of the shaft,measured at a specified distance from the end of the shaft,when the body of the item is held fixed and the shaft is rotated with a specified load applied radially to the shaft.AEFZ
Shaft Runout:
0.001 inches
MRC:
The perpendicularity of the mounting surface,with respect to the rotational axis of the shaft,and measured on the mounting surface at a specified distance from the outside edge of the mounting surface,when the shaft is held fixed and the body of the item is rotated with specified loads applied radially and axially to the body of the item.AEGA
Lateral Runout:
0.002 inches
MRC:
The eccentricity of the pilot diameter with respect to the rotational axis of the shaft and measured on the pilot diameter when the shaft is held and the body of the item is rotated while a specified load is applied radially to the body.AEGB
Pilot Diameter Runout:
0.00100 inches
MRC:
The total radial excursion of the shaft measured at a specified distance from the front surface of the unit with a specified radial load applied alternately in opposite directions at a specified point.AEGC
Shaft Radial Play:
0.001 inches
MRC:
The maximum difference of shaft position that occurs when the shaft is moved to the same actual output ratio point from opposite directions,expressed in degree angular rotation.AEGD
Mechanical Backlash In Deg Angular Rotation:
0.041
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Radially positioned over more than half the circumference
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp ring
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
5.000 kilohms all sections
MRC:
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
Rotary Actuator Travel In Angular Deg:
360.0
MRC:
The change in total resistance over a specified temperature range per section,expressed as a percent of the total resistance at a specified reference temperature.CQDB
Resistance Tempurature Characteristic Range Per Section In Percent:
-5.0/+5.0 -65 degrees celsius all sections and -4.0/+4.0 -15 degrees celsius all sections and -2.5/+2.5 50 degrees celsius all sections and -5.0/+5.0 75 degrees celsius all sections and -5.0/+5.0 105 degrees celsius all sections and -5.0/+5.0 125 degrees celsius all sections
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.05/+0.05 1st section
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.10/+0.10 2nd section
MRC:
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
125.0 all sections
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
2.0 free air all sections
MRC:
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
Function Conformity Per Section:
All sections independent linearity
MRC:
The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
Fixed Tap Quantity Per Section:
1 1st section
MRC:
The limits of permissible variation from the rated value of the location of a tap per section.CRKS
Tap Location Tolerance Per Section:
-250.0/+250.0 ohms 1st section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-10.0/+10.0 all sections
MRC:
The feature that controls the actuator travel.CRSX
Actuator Travel Control Feature:
Stops
MRC:
Indicates the location of a tap relative to the counterclockwise terminal per section,expressed in ohms.CSBW
Tap Location From Ccw Terminal Per Section In Ohms:
2500.0 1st section
MRC:
The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
Function Characteristic Per Section:
All sections linear
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
40.0 all sections
MRC:
The measured weight of an item unencumbered by packaging or packing material.PKWT
Unpackaged Unit Weight:
168.00 grams
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
03538-7648736 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
7 turret