Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Epoxy paint finish
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Motor-tachometer Generator				
			 
			
							
										
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.AAJT
					 
					
						Overall Height:
					
					
						7.750 inches					
				 
							
					
						MRC:
						A measurement of the longest dimension of an item,in distinction from width.AAJU
					 
					
						Overall Length:
					
					
						19.250 inches					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
					 
					
						Overall Width:
					
					
						6.250 inches					
				 
							
					
					
						Flatted Portion Length:
					
					
						0.5000 inches  single end					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac input					
				 
							
					
						MRC:
						A measurement of the longest dimension of a keyway,in distinction from width.AFYS
					 
					
						Keyway Length:
					
					
						1.0000 inches  single end					
				 
							
					
					
						Flat Depth:
					
					
						0.0370 inches  single end					
				 
							
					
						MRC:
						An indication of the feature/s/ of the inclosure.ANPZ
					 
					
						Inclosure Feature:
					
					
						Totally enclosed					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Pad					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 unthreaded hole					
				 
							
					
						MRC:
						The speed at which the calibration is determined,expressed in revolutions per minute.BFLQ
					 
					
						Calibration Speed In Rpm:
					
					
						1000.0					
				 
							
					
						MRC:
						The means of cooling used to maintain the required operating temperature of the item.BFMF
					 
					
						Cooling Method:
					
					
						Fan cooled					
				 
							
					
						MRC:
						An indication of the type of calibration voltage output,expressed in volts.BKPC
					 
					
						Calibration Voltage Output Type In Volts:
					
					
						3.3 ac					
				 
							
					
						MRC:
						Indicates the torque rating,and its type.BKPH
					 
					
						Torque Rating And Type:
					
					
						17.5 foot-ounces stalled					
				 
							
					
						MRC:
						The government or industrial specification or standard that defines the inclosure feature.BKPQ
					 
					
						Inclosure Specificationification:
					
					
						Commercial					
				 
							
					
						MRC:
						Indicates the type of control field voltage and its rating,expressed in volts.BKPS
					 
					
						Control Field Voltage Type And Rating In Volts:
					
					
						115.0 ac					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Horizontal mounting position and vertical mounting position					
				 
							
					
						MRC:
						The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
					 
					
						Criticality Code Justification:
					
					
						Feat					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
					 
					
						Length Of Shaft From Housing:
					
					
						1.125 inches single end					
				 
							
					
						MRC:
						The speed rating of a rotor,expressed in revolutions per minute.CWFX
					 
					
						Rotor Speed Rating In Rpm:
					
					
						7250.0 single no load and 2000.0 single full load					
				 
							
					
						MRC:
						The nominal center to center distance between the mounting facilities parallel to the width.CWFY
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						5.125 inches					
				 
							
					
						MRC:
						The nominal center to center distance between the mounting facilities parallel to the height.CWGD
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Height:
					
					
						5.125 inches					
				 
							
					
						MRC:
						The amount of current for which an item is rated,expressed in amperes.CWGL
					 
					
						Current Rating In Amps:
					
					
						22.000 single input					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Two input					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						400.0 output					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						24930-129197f specification (includes engineering type bulletins,  brochures, etc.,  that reflect specification type data in specification format;  excludes commercial catalogs,  industry directories,  and similar trade publications,  reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical",  "average",  "",  etc.).