Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Graduated Scale Hydrometer				
			 
			
										
					
						MRC:
						The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
					 
					
						Stem Material:
					
					
						Glass					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						7.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						0.563 inches 					
				 
							
					
						MRC:
						The number of scales on the item.APSJ
					 
					
						Scale Quantity:
					
					
						1					
				 
							
					
						MRC:
						An indication of the scale range.APSK
					 
					
						Scale Range:
					
					
						+6.5/+7.6 pounds per gallon					
				 
							
					
						MRC:
						The nomenclature by which the scale is identified.AQFZ
					 
					
						Scale Name:
					
					
						Density in pounds per gallon					
				 
							
					
						MRC:
						The element,compound,or mixture of which the plummet is fabricated,excluding any surface treatment.AWAD
					 
					
						Plummet Material:
					
					
						Glass					
				 
							
					
						MRC:
						The smallest value between the markings on a scale.AWAG
					 
					
						Scale Smallest Increment:
					
					
						0.05 pounds					
				 
							
					
						MRC:
						The minimum and maximum deviation from the exact reading of the scale.AWAH
					 
					
						Scale Accuracy Rating:
					
					
						0.025 pounds per gallon					
				 
							
					
						MRC:
						A value which expresses the temperature at which the scale is calibrated.AWAJ
					 
					
						Scale Calibration Temp:
					
					
						60.0 degrees fahrenheit					
				 
							
					
						MRC:
						An indication of whether or not a thermometer is included.AWAK
					 
					
						Thermometer:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a specimen receptacle holder is included.AWAL
					 
					
						Specimen Receptacle Holder:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a correction scale is included.AWAN
					 
					
						Correction Scale:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a conversion chart is included.AWAQ
					 
					
						Conversion Chart:
					
					
						Not included					
				 
							
					
						MRC:
						The technical differentiating characteristic/s/ of an item of supply which depart/s/ from the text of a specification or a standard in that it represents a selection of characteristics stated in the specification or standard as being optional,or a variation from one or more of the stated characteristics,or an additional characteristic not stated in the specification or standard.ZZZW
					 
					
						Departure From Cited Document:
					
					
						Paragraphs 3.4.1.3, 3.4.1.3.1, 3.4.1.3.2, 3.4.1.3.3, 3.4.1.3.4, 3.4, 1.3.5