Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Oscilloscope
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
15.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
11.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.200 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Oscilloscope
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Os-208a/upm-137
MRC:
The means of attaching the item.AXGY
Mounting Method:
Cabinet w/complete hardware for rack
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-3.0/+3.0
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-3.0 to 3.0
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
An indication of whether or not a generator driven feature is included.BGQM
Generator Driven Feature:
Included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal
MRC:
The length of time consumed by a single trigger sweep.BGQQ
Single Trigger Sweep Duration:
Between 1.0 microseconds and 20.0 milliseconds
MRC:
The maximum absolute value for which the trigger sweep voltage is rated.BGRZ
Trigger Sweep Voltage Amplitude Rating:
Between 0.05 volts and 20.0 volts
MRC:
An indication of whether or not a trigger sweep polarity switch is included.BGSB
Trigger Sweep Polarity Switch:
Included
MRC:
The distance between indicated pulse intervals shown on the screen of a trigger sweep designed item.BGSC
Trigger Sweep Marker Intervals:
0.1 usec, 0.1 and 1 usec, 1 usec, 1.45 usec, 5 usec, 50 usec
MRC:
An indication of whether or not an expanded sweep is provided.BGSD
Expanded Sweep:
Not provided
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Not provided
MRC:
An indication of whether or not provisions for rating the direct connection to the plate deflection sensitivity is provided.BHDL
Plate Direct Connection Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Provided
MRC:
The minimum and maximum frequencies to which the y-axis will respond.BHDR
Y-axis Frequency Response Rating:
Between 0.0 megahertz and 8.0 megahertz
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Not provided
MRC:
An indication of the shape of the amplitude calibrating voltage waveform.BHDZ
Amplitude Calibrating Voltage Waveform:
Square wave
MRC:
The peak to peak value for which the item is calibrated.BHFB
Calibrating Peak To Peak Amplitude:
Between 0.2 volts and 20.0 volts
MRC:
The number of measurement ranges included.BHFC
Measurement Range Quantity:
7
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Not included
MRC:
An indication of the function of the plug in units and the number provided.BHFS
Plug In Unit Function And Quantity:
Vide0 input 2 and external sync input 1
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Not provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single