Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Variable Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.20
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
1.0 watts average
MRC:
The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
Overall Attenuation Range In Decibels:
+0.0/+22.1
MRC:
The frequency at which the attenuation accuracy was measured.ASYE
Attenuation Accuracy Reference Frequency:
500.0 megahertz
MRC:
The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
Attenuation Variation Method:
Stepped
MRC:
The number of intervals at which the item can be set.ASYG
Step Position Quantity:
10
MRC:
The amount of attenuation between adjacent steps,expressed in decibels.ASYH
Attenuation Per Step In Decibels:
0.1 and 0.2 and 0.3 and 0.5 and 1.0 and 2.0 and 3.0 and 5.0 and 10.0 and 22.1
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 0.000 hertz and 1000.000 megahertz
MRC:
The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
Overall Attenuation Accuracy In Decibels:
-0.50/+0.50
MRC:
The minimum and maximum limits of attenuation within the overall attenuation range for which a related accuracy value has been specified,expressed in decibels.BQNS
Segment Attenuation Range In Decibels:
+0.00/+0.10 and +0.10/+0.20 and +0.20/+0.30 and +0.30/+0.50 and +0.50/+1.00 and +1.00/+2.00 and +2.00/+3.00 and +3.00/+5.00 and +5.00/+10.00 and +10.00/+22.10
MRC:
The limits of permissible variation in the attenuation accuracy at any point between two specified attenuation values within the overall range of the item,expressed in decibels.BQNT
Segment Attenuation Accuracy In Decibels:
-0.50/+0.50
MRC:
Indicates the type and number of facilities for adjusting the item.CQTQ
Adjustment Device Type And Quantity:
9 toggle
MRC:
The total opposition (resistive and reactive) to the flow of alternating current,expressed in ohms.CTGG
Impedance Rating In Ohms:
50.0 input-output
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equip