Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Scale marked batt at 150; conductive glass window
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Roentgen Rate Meter
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Round, flush mounting
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
2.780 inches
MRC:
An overall measurement of the smallest dimension of a panel,in distinction from length or width.ADEE
Panel Thickness:
0.090 inches
MRC:
The length of a straight line which passes through the center of a mounting flange,and terminates at the outside circumference.ADME
Mounting Flange Outside Diameter:
4.580 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Steel
MRC:
The hue or tint of the light emitted from that portion of the item which surrounds the inscription on the item.AETT
Inscription Background Color:
White
MRC:
An indication of whether or not a magnetic shield is included.AHFT
Magnetic Shielding:
Not included
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
6 no. 6-32 thd mtg studs equally spaced on 2.062 in. Radius
MRC:
The increment of measure represented by the marking/s/ on the item.ANBJ
Graduation Unit:
50.0 roentgens
MRC:
The element,compound,or mixture of which the panel is fabricated,excluding any surface treatment.ANJG
Panel Material:
Steel
MRC:
An indication of the type of meter.ANTH
Meter Type:
Mounted
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-1.0/+1.0 at full scale
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-1.0 to 1.0 at full scale
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+500.0 roentgens
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0 to 500.0 roentgens
MRC:
An indication of the meter design.APSL
Meter Style:
Panel
MRC:
An indication of the sensitivity of the item.APSM
Err Default:
Err default
MRC:
An indication of the sensitivity of the item.APSM
Sensitivity:
500 ua at full scale deflection
MRC:
An indication of the panel for which the item is designed.APSN
Panel For Which Designed:
Magnetic
MRC:
An indication of whether or not the dial scale markings are luminous.APSQ
Dial Scale Marking Luminosity:
Nonluminous
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
1.150 inches