Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radio Frequency Interfere Filter
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 1st radio interference
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 3rd radio interference
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 2nd radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
30.0 2nd radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
30.0 3rd radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
30.0 1st radio interference
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
3 connector, receptacle output 2nd function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
3 connector, receptacle input 1st function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on one surface