Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Pressure And Temper Relief Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum alloy 6061-t6 fscm 06177
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
Outside Surface Treatment:
Anodized mil-a-8625 type 3
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Single connection angle flow
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
275.0 degrees fahrenheit
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydrocarbon fuels and oils
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded external tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
External seat for gasket seal
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.500 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
0.750-16 unjf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
First End Thread Class:
3a
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel, aisi 440c
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
1
MRC:
The predetermined pressure at which the item is calibrated to open.ADSV
Opening Pressure Setting:
Not rated
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
0.3 gallons per minute
MRC:
An indication of whether or not the temperature is adjustable.AEVX
Tempurature Adjustability:
Not adjustable
MRC:
Indicates the type of temperature control device that actuates the item.AFKX
Tempurature Control Device Type:
Thermostatic