Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Fifth grouping arrangement tenth, eleventh and twelfth conductor through fifty-fifth, fifty-sixth and fifty-seventh conductor
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrical Special Purpose Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
105.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
1.358 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
57
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
20 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
32 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
19 triples
MRC:
Indicates the type and number of conductor arrangements within groups.CXDY
Conductor Grouping Arrangement Type And Quantity:
19 triples all groups
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
First conductor first group and second conductor first group and third conductor first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Fourth conductor second group and fifth conductor second group and sixth conductor second group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Seventh conductor fourth group and eighth conductor fourth group and ninth conductor fourth group
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy 101 core conductor all conductors or copper alloy 102 core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinyl chloride 1st position primary insulation all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber chloroprene class cr 1st position jacket cable
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b33 assn standard all material responses core conductor all conductors
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Astm b33-63 assn standard single treatment response core conductor all conductors