Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Dial Indicating Pressure Gage
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.100 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.000 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum alloy, 2024
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Anodized black
MRC:
The increment of measure represented by the marking/s/ on the item.ANBJ
Graduation Unit:
100.0 pounds per square inch
MRC:
Indicates the type of actuation provided.APCM
Actuation Type:
Bourdon tube
MRC:
An indication of whether or not the item is adjustable.APCS
Adjustability:
Nonadjustable
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+4000.0 pounds pressure per square inch
MRC:
The nomenclature by which the scale is identified.AQFZ
Scale Name:
Pounds pressure
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Any acceptable
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Indicating
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Dial
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
100.0 pounds per square inch
MRC:
The degree of conformity of a scale measurement to a standard or a true value.BGKS
Scale Accuracy:
Porm 80 psi
MRC:
The element,compound,or mixture of which an actuating element is fabricated,excluding any surface treatment.BGKY
Actuating Element Material:
Nickel-chromium alloy
MRC:
The element,compound,or mixture of which the protective crystal is fabricated,excluding any surface treatment.BHMF
Protective Crystal Material:
Glass, dd-g-451, type 2, class 1, quality q4
MRC:
An indication of whether or not a connector type vent is provided.BHMK
Connector Type Vent:
Not provided