Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Heating Radiator Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Bronze
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
150.0 pounds per square inch err-100
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
15.0 pounds per square inch err-100
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle give "adqm" and "adqn" only if flanged one or two ends
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
250.0 degrees fahrenheit
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Steam err-100 err-100
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh err-100 err-100
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACLG
First End Pipe Size Accommodated:
1.000 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
1.000-11-1/2 npt
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Threaded external pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACMN
Second End Pipe Size Accommodated:
1.000 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACMQ
Second End Thread Size And Series/type Designator:
1.000-11-1/2 npt
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
Second End Thread Direction:
Right-hand
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The designation which is used for the purpose of general identification of the nominal thread size.CQYM
First End Thread Size:
1.000 inches
MRC:
The designation which is used for the purpose of general identification of the nominal thread size.CRNB
Second End Thread Size:
1.000 inches