						Informationen zum Teil
						Consisting ofquantity type 2 80103, lds-y-5-ov-4006-2; quantity type 2 80103, lds-x-15-40062 l-12-ov-15; quantity type 1 80103, lns-y-12-40063 l-6-ov-12; quantity type 1 80103 lds-y-24-40062 l-6-ov-24; quantity type 1 80103 lra-17
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Power Supply Assembly				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						21.000 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						5.187 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						19.000 inches 					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Fungus proof					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						An/fps-115					
				 
							
					
						MRC:
						The relationship of the electrical power source to the item.AKWC
					 
					
						Electrical Power Source Relationship:
					
					
						Operating					
				 
							
					
						MRC:
						The input value/s/,or range of values,for which the item is rated.APNX
					 
					
						Input Voltage Rating:
					
					
						210.0 ac pounds per hour dry 2nd alternate operating power rqmt and 254.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt					
				 
							
					
						MRC:
						The input value/s/,or range of values,for which the item is rated.APNX
					 
					
						Input Voltage Rating:
					
					
						105.0 ac pounds per hour dry 1st alternate operating power rqmt and 127.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						15.0 dc volts  2nd power output					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						24.0 dc volts  1st power output					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						-15.0 dc volts  6th power output					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						-5.0 dc volts  5th power output					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						12.0 dc volts  3rd power output					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						5.0 dc volts  4th power output					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
					 
					
						Input Frequency Rating:
					
					
						47.0 hertz  single operating power rqmt and 440.0 hertz  single operating power rqmt					
				 
							
					
						MRC:
						The ambient temperature range at which the item is designed to operate.AYNH
					 
					
						Operating Ambient Tempurature Range:
					
					
						-0.0/+60.0 degrees celsius					
				 
							
					
						MRC:
						Indicates the type of design provided for ventilation of the item.CWKG
					 
					
						Ventilation Design Type:
					
					
						Convection