Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Low Pass Filter
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
15.375 inches
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
425.0 megahertz blank
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
50.0 ohms blank
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
50.0 ohms blank
MRC:
The ratio of the maximum to the minimum voltage of the standing wave per function. the larger relative portion is given,the lower value having an implied /not given/ value of one /unity/.AHBZ
Voltage Standing Wave Ratio Per Function:
2.0 blank
MRC:
The value of the average amount of electrical energy per function,which the item may pass or dissipate in continuous operation without degradation of physical or electrical characteristics.AHCH
Average Power Rating Per Function:
5.0 kilowatts blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Uninclosed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 flange
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
179.0 cubic inches
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
0.25 blank
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 circular flange input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 circular flange output 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
400.00 megahertz blank and 450.00 megahertz blank and 800.00 megahertz blank and 2.25 gigahertz blank
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
400.00 megahertz blank and 450.00 megahertz blank
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
1.0 blank and 1.0 blank and 27.0 blank and 20.0 blank
MRC:
The minimum and maximum values of frequency,per function,between which the voltage standing wave ratio is specified.CRBN
Voltage Standing Wave Ratio Frequency Limits Per Function:
400.0 megahertz blank and 450.0 megahertz blank
MRC:
The measured weight of an item unencumbered by packaging or packing material.PKWT
Unpackaged Unit Weight:
2.500 pounds