Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
24.000 in. Min, 26.000 in. Maximum lg wire leadconnections
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Liquid Level Switch
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
110.0 volts
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
220.0 volts
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
110.0 volts 1st operating power rqmt
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
220.0 volts 2nd operating power rqmt
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
32.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
6.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
32.0 volts 4th operating power rqmt
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
6.0 volts 3rd operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
3.000 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
45.0 milliamperes resistive load
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Not rated
MRC:
The means of attaching the item.AXGY
Mounting Method:
Thread
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The maximum continuous current which must not be exceeded in order to avoid damage to the item.BJKC
Maximum Current Rating:
500.0 milliamperes resistive load
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Single throw, normally open
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Fuel, nonaircraft and hydraulic oil and water
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
Mtd by 3/4 in.Pipe thd connections at inlet and outlet
MRC:
The number of alternating current phases.FAAZ
Phase:
Single