Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Centrifugal Pump Unit				
			 
			
										
					
						MRC:
						The number of prime movers incorporated in the unit.AAXH
					 
					
						Prime Mover Quantity:
					
					
						1					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
					 
					
						Prime Mover Cooling Medium:
					
					
						Air					
				 
							
					
						MRC:
						Indicates the type of mount utilized to support the item.AAXX
					 
					
						Mounting Type:
					
					
						Base					
				 
							
					
						MRC:
						The number of stages incorporated in the item.AAYD
					 
					
						Stage Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of discharge connections included on the item.AAYV
					 
					
						Discharge Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of discharge connection included on the item.AAYW
					 
					
						Discharge Connection Type:
					
					
						Unthreaded external					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Dc					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Water,  fresh or water,  salt					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Watertight					
				 
							
					
						MRC:
						The number of pumps incorporated in the item.AENC
					 
					
						Pump Quantity:
					
					
						1					
				 
							
					
						MRC:
						The means of cooling used to maintain the required operating temperature of the item.AENK
					 
					
						Cooling Method:
					
					
						Self ventilated					
				 
							
					
						MRC:
						The maximum rated capacity delivered by the item.AHYV
					 
					
						Maximum Discharge Flow Rate:
					
					
						33.3 gallons per minute					
				 
							
					
						MRC:
						The sum of the total discharge head and the total suction lift.AHYX
					 
					
						Total Head:
					
					
						17.000 feet					
				 
							
					
						MRC:
						The position in which the pumping element/s/ is designed to operate.AHZA
					 
					
						Pumping Element Operating Position:
					
					
						Vertical					
				 
							
					
						MRC:
						The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
					 
					
						Centrifugal Pump Design:
					
					
						Mixed flow					
				 
							
					
						MRC:
						The number of impellers incorporated in the centrifugal pump.AHZF
					 
					
						Centrifugal Pump Impeller Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
					 
					
						Centrifugal Pump Impeller Suction Type:
					
					
						Single					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of an item unencumbered by packaging or packing,in distinction from thickness.AJAG
					 
					
						Unpackaged Unit Width:
					
					
						4.2500 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of an item unencumbered by packaging or packing,in distinction from depth.AJAH
					 
					
						Unpackaged Unit Height:
					
					
						6.000 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of the basic material of which the major portion of the pump is fabricated.AJAL
					 
					
						Pump Basic Material:
					
					
						Plastic					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The electrical current rating,expressed in amperes.AMPS
					 
					
						Current Rating In Amps:
					
					
						12.0					
				 
							
					
						MRC:
						The rated power of the prime mover.CSYL
					 
					
						Prime Mover Power Rating:
					
					
						144.0 watts					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						12.0