Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
20006-627b8-1
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrical Coil Assembly
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
29-1/2 all components single winding
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.281 inches single group
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
85.00 henry all components single winding
MRC:
The designation describing the method used in forming the core.ACZR
Core Construction:
S0lid all components
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
6.375 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
6.375 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.125 inches
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1 all components
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns all components single winding
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.11440 inches american wire gage all components single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 cable w/connector