Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.700 inches
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
200.0 ac volts 2nd operating power rqmt and 260.0 ac volts 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
100.0 ac volts 1st operating power rqmt and 130.0 ac volts 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
12.0 dc volts 1st power output and 24.0 dc volts 1st power output and 117.0 ac volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
45.0 hertz 2nd operating power rqmt and 65.0 hertz 2nd operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
45.0 hertz 1st operating power rqmt and 65.0 hertz 1st operating power rqmt
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Input filter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 dc amperes 1st power output and 1.0 dc amperes 1st power output and 500.0 ac milliamperes 1st power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Single 1st power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Single 2nd power output