Teilenummer 20082C0DE1013

Lever Switch

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
20082c0de1013
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
006696879
NSN
Nationale Bestandsnummer:
5930-00-669-6879 5930006696879
TXT
Beschreibung:
Lever Switch
INC
INC
Artikelname-Code:
00175
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.562 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.750 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.750 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.250 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.062 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
Center To Center Distance Between Mounting Facilities Parallel To Height:
0.812 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Round
MRC:
None.AFUS
Actuator Height:
1.000 inches
MRC:
The relationship between the actuator position and the actuator action /maintained or momentary/.AFUX
Actuator Position-action Relationship:
Up position maintained and down position maintained and center position maintained
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
48.0 dc
MRC:
The basic contact forms,in the order of assemblage,that collectively describe the switching structure of a pile-up contact group.CQDK
Pile-up Contact Form Arrangement:
4c 1st position
MRC:
The basic contact forms,in the order of assemblage,that collectively describe the switching structure of a pile-up contact group.CQDK
Pile-up Contact Form Arrangement:
4c 2nd position
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
5.000 amperes resistive dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 tab, solder lug

Ähnlich Lever Switches

« Switches {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken