Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Operated Drum Winch
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The means used to operate the item.APHE
Operation Method:
Power
MRC:
The distance between flanges on the drum,and the location on the item.ATWD
Drum Flange To Flange Distance And Location:
8.000 inches first drum
MRC:
The length of a straight line which passes through the center of the drum,and terminates at the circumference,and its location on the item.ATWE
Drum Diameter And Location:
4.500 inches first drum
MRC:
The length of a straight line which passes through the center of the drum flange,and terminates at the circumference,and its location on the item.ATWF
Drum Flange Diameter And Location:
8.000 inches first drum
MRC:
The power required to start and operate the item at rated capacity.ATYG
Power Requirement Rating:
40.00 horsepower
MRC:
The design on the drum surface.ATYH
Drum Surface Design:
Plain
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Non ventilated
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0