Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					 Nonwire Wound Variable Resistor				
			 
			
										
					
						MRC:
						The number of individual elements.AAPN
					 
					
						Section Quantity:
					
					
						2					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical servo mounted					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
					 
					
						Pilot Diameter:
					
					
						1.00000 inches 					
				 
							
					
						MRC:
						The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
					 
					
						Pilot Length:
					
					
						0.06700 inches 					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						3.820 inches 					
				 
							
					
					
						Undercut Diameter:
					
					
						1.880 inches 					
				 
							
					
					
						Undercut Width:
					
					
						0.05700 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						2.020 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
					 
					
						Shaft Diameter:
					
					
						Between 0.2494 inches and 0.2497 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft,in distinction from width.ABXF
					 
					
						Shaft Length:
					
					
						Between 0.430 inches and 0.470 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						1.800 inches 					
				 
							
					
					
						Mounting Lip Diameter:
					
					
						Between 1.99500 inches and 2.00500 inches 					
				 
							
					
					
						Mounting Lip Depth:
					
					
						0.09800 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
					 
					
						Shaft Style:
					
					
						Round					
				 
							
					
						MRC:
						Indicates the type of shaft bearing/s/ furnished.AEDZ
					 
					
						Shaft Bearing Type:
					
					
						Ball					
				 
							
					
						MRC:
						Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
					 
					
						Actuator Type:
					
					
						Single shaft					
				 
							
					
						MRC:
						That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
					 
					
						Effective Electrical Rotation In Deg Angular Rotation:
					
					
						347.0 					
				 
							
					
						MRC:
						The position of the terminal/s/ for making connection to an item.APXH
					 
					
						Terminal Location:
					
					
						Radially positioned over less than half the circumference					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Clamp ring					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						10.000 ohms 1st section and 28.000 ohms 2nd section					
				 
							
					
						MRC:
						The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
					 
					
						Function Conformity Tolerance Per Section:
					
					
						-0.50/+0.50 all sections					
				 
							
					
						MRC:
						A constant that represents the proportionate change in resistance caused by a change in temperature per section,expressed in parts per million per degree celsius.CRFJ
					 
					
						Tempurature Coefficient Of Resistance Per Section In Ppm Per Deg Celsius:
					
					
						-400.0/+400.0 all sections					
				 
							
					
						MRC:
						The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
					 
					
						Power Dissipation Rating Per Section In Watts:
					
					
						0.1 free air 1st section and 0.07 free air 2nd section					
				 
							
					
						MRC:
						The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
					 
					
						Function Conformity Per Section:
					
					
						All sections absolute conformity					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
					 
					
						Resistance Tolerance Per Section In Percent:
					
					
						-10.0/+10.0 single section					
				 
							
					
						MRC:
						The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
					 
					
						Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
					
					
						125.0 all sections					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						6 turret