Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Fuel rate of flow indicator
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Rate Of Flow Indicator
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
2.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
6.920 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
15
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Pin
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Rate of flow
MRC:
Indicates the type of presentation.AMNL
Presentation Type:
Counter and dial
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+100000.0 pounds per hour single indicator all scales
MRC:
An indication of the individual marking on the item.ASKN
Individual Marking:
Fuel flow; pph x 1000
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
Jt1h14-15p
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Indicating single pointer
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Hermetically sealed case
MRC:
The length of a straight line which passes through the center of the dial,and terminates at the outside circumference.CXQH
Dial Outside Diameter:
1.960 inches
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
5 vac lighting; accuracy +/-500 pph; counter range 0-100, 000 pph; counter accuracy: 0-20, 000 pph +/-100 pph a20, 000 to 100, 000 pph +/- 250 pph; weight 1.10 lbs
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Tech order 5l6-2-53-3