Teilenummer 207277

Power Switchboard

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
207277
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
000335433
NSN
Nationale Bestandsnummer:
6110-00-033-5433 6110000335433
TXT
Beschreibung:
Power Switchboard
INC
INC
Artikelname-Code:
02795
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
36.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
83.562 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
132.250 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Deck
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Cva59-60 vessels
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Shipboard emergency power and lighting distribution
MRC:
The name designation of the written or printed document.ALYQ
Document Title:
Components and accessories listed on buships dwg no. Cva60-s6201-1487967
MRC:
The element,compound,or mixture of which the panel is fabricated,excluding any surface treatment.ANJG
Panel Material:
Steel
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three 1st voltage rating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three 2nd voltage rating
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Open
MRC:
The number of complete cyclic changes,per unit of time,for which the output frequency is rated.ANSQ
Output Frequency Rating:
60 hertz
MRC:
The number of panels provided.APCA
Panel Quantity:
11
MRC:
The number of electrical inputs accommodated.APNW
Electrical Input Quantity:
6
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac volts 2nd voltage rating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
450.0 ac volts 1st voltage rating
MRC:
An indication of whether or not an input neutral is provided.APNY
Input Neutral:
Not provided
MRC:
The number of electrical outputs provided.APNZ
Electrical Output Quantity:
67
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
120.0 ac volts 4th voltage rating
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
120.0 ac volts 5th voltage rating
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
450.0 ac volts 1st voltage rating
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
450.0 ac volts 2nd voltage rating
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
450.0 ac volts 3rd voltage rating
MRC:
An indication of whether or not an output neutral is provided.APPC
Output Neutral:
Not provided
MRC:
The amount of impact or shock an item is rated to withstand.APPD
Shock Absorbent Rating:
N hi-shockproof
MRC:
The cycles per second /hertz/ of input alternating current.APPY
Input Frequency In Hertz:
60.0 1st voltage rating
MRC:
The cycles per second /hertz/ of input alternating current.APPY
Input Frequency In Hertz:
60.0 2nd voltage rating
MRC:
The number of alternating current phases.FAAZ
Phase:
Three 1st voltage rating
MRC:
The number of alternating current phases.FAAZ
Phase:
Three 2nd voltage rating
MRC:
The number of alternating current phases.FAAZ
Phase:
Three 3rd voltage rating
MRC:
The number of alternating current phases.FAAZ
Phase:
Three 4th voltage rating
MRC:
The number of alternating current phases.FAAZ
Phase:
Three 5th voltage rating
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel