Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Motor Starter
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
0 to full speed
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
General purpose-nema type 1
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.812 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Automatic and manual
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four mtg holes on 7-1/4 in. By 5-1/2 in. Mtg ctr
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
1.500
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
115.0 dc
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Overload
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
General purpose
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Not designed per nema std
MRC:
An indication of the various functional switching positions.ANRK
Switch Functional Positions:
Reset
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Accessory location external