Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
212-bw621-1s-fw-ffw-1214
Informationen zum Teil
Second end has floating flange which moves or rotateafter assembly
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Metallic Hose Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
2.500 inches
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
68.0 degrees fahrenheit single response
MRC:
The length of a straight line which passes through the center of a bolt circle,and terminates at the circumference.ABKG
Bolt Circle Diameter:
5.500 inches 1st end
MRC:
The length of a straight line which passes through the center of a bolt circle,and terminates at the circumference.ABKG
Bolt Circle Diameter:
5.500 inches 2nd end
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
0.875 inches 1st end
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
0.875 inches 2nd end
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
3.370 inches
MRC:
The minimum inside bending radius formed without stressing or deformation of a flexible item.ACKH
Minimum Inside Bending Radius:
13.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the inner conveying tube.ADJL
Inner Conveying Tube Style:
Annular close-pitch corrugated
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
4 1st end
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
4 2nd end
MRC:
The length of a straight line which passes through the center of the flange,and terminates at the outside circumference.AEPR
Flange Outside Diameter:
7.000 inches 1st end
MRC:
The length of a straight line which passes through the center of the flange,and terminates at the outside circumference.AEPR
Flange Outside Diameter:
7.000 inches 2nd end
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Engine, aircraft, f100-pw-100 (f-15a/b/c/d; 4920013901852
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain 1st end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain 2nd end
MRC:
The length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.AHNX
Bolt Hole Diameter:
0.750 inches 1st end
MRC:
The length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.AHNX
Bolt Hole Diameter:
0.750 inches 2nd end
MRC:
The design used in constructing the end portion of the flange.AKUT
End Flange Construction:
Solid 1st end
MRC:
The design used in constructing the end portion of the flange.AKUT
End Flange Construction:
Solid 2nd end
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 1st end
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Plain face flange 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Plain face flange 2nd end
MRC:
The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
Burst Test Pressure:
1000.0 pounds per square inch
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
Outer layer braided corrosion resistant steel wire
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
250.0 pounds per square inch
MRC:
A steady,uniform,internal,static pressure that the item must withstand without leakage,abnormal distortion,or damage.CRDW
Hydrostatic Test Pressure:
500.0 pounds per square inch
MRC:
The means used and the measurement of the longest dimension of an item.CRXX
Measuring Method And Length:
12.250 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Round w/ bolt holes 1st end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Round w/ bolt holes 2nd end