Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Mfg name nanovoltmeter. For applications such as thermocouple testing or low-resistance measurements including bus bar testing; low-resistance shunt measurements and superconductor measurements. Dual channel; bult-in thermocouple; 3 ways to measure nanovolts
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Voltmeter
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac and dc
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
14.563 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.125 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.375 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 45.0 hertz and 440.0 hertz
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Low thermal in-put cable, with spade lugs 4 ft long; users manual; service manual; contact cleaner; line cord; alligator clips
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
Indicates the type of display provided.BFQN
Display Type:
Light emitting diode
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
7-1/2
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 volts 2nd indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 volts 1st indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 millivolts 1st indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 volts 1st indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 volts 2nd indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 millivolts 1st indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 millivolts 2nd indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 volts 1st indicator 5th range
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
1 screw
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
Between 100.0 ac and 240.0 ac
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Portable w/tilt view handle